coder.asap2.AxisInfo
R2026bDescription
Create an axis info object to define axis for a lookup table element and export it to an ASAP2 file.
Creation
creates an axis
object. You can use the object to define axis for a lookup table element and export it to an
ASAP2 file.axis = coder.asap2.AxisInfo
Properties
Specify a name for the custom axis object.
Example:
"CustomLUT_1"
Specify comments and description of the custom axis object.
Example:
"Description of the LUT"
Address of the element in memory.
Example:
0x0000
Name of the record layout.
Example:
"Record_DATATYPE"
Type of the axis.
Example:
"FIX_AXIS"
Name of the measurement to be used as input quantity for the corresponding axis.
Example:
'NO_INPUT_QUANTITY'
Name of the conversion method.
Example:
"COMPU_METHOD_1"
Maximum number of axis points.
Example:
[4]
Possible minimum value.
Example:
[1.5]
Possible maximum value.
Example:
[11.5]
Reference to the AXIS_PTS record for description of the axis points distribution.
Example:
"AXIS_PTS_REF_1"
Type of the fix axis.
Example:
"FIX_AXIS_PAR"
Distance attribute for FIX_AXIS_PAR and
FIX_AXIS_PAR_DIST.
Example:
2.3
Offset attribute for FIX_AXIS_PAR,
FIX_AXIS_PAR_DIST, and list of values for
FIX_AXIS_PAR_LIST.
Example:
0.3
Display format of the object in calibration tool.
Example:
"%4.2"
Display name of the object in calibration tool.
Example:
"Custom name"
Specify the calibration access type for the custom axis info object.
Example:
"Calibration"
Specify symbols for address replacement.
Example:
"/* @ECU_Address@AXIS_1@ */"
Additional address information to distinguish different address spaces of an ECU (multi-micro controller devices).
Example:
1
Reference to symbol name within a linker map file.
Example:
struct('SymbolName','p1_SymbolName','Offset',1)
Maximum refresh rate.
Example:
struct('ScalingUnit',ScalingUnits.ONE_MILLI_SEC,'Rate',100)
Specify any additional description that needs to be populated in the axis.
Example:
"additional information"
Examples
This example shows how to programmatically customize ECU descriptions in an ASAP2 file by adding, modifying, and removing computation methods, characteristics, measurements, and lookup table parameters.
Use functions to create an ECU description object from a built model, find and filter its contents, and export a customized ASAP2 file.
In this example, you:
Build a model and create an ECU description object
Find and filter computation methods by properties
Add and modify a custom computation method
Add and modify a custom characteristic and measurement
Add a lookup table parameter with axis information
Export the customized ASAP2 file
Open and Build the Model
Open the example model ASAP2Demo and generate code from it. Building the model is a prerequisite for creating the ECU description object.
open_system("ASAP2Demo");
slbuild("ASAP2Demo");### Searching for referenced models in model 'ASAP2Demo'. ### Total of 2 models to build. ### Starting serial code generation build. ### Starting model reference code generation target build for: ASAP2DemoModelRef ### Successfully updated the model reference code generation target for: ASAP2DemoModelRef ### Starting top model code generation target build for: ASAP2Demo ### Successful completion of build procedure for: ASAP2Demo Build Summary Model reference code generation targets: Model Build Reason Status Build Duration ============================================================================================================ ASAP2DemoModelRef Target (ASAP2DemoModelRef.c) did not exist. Code generated and compiled. 0h 0m 8.5322s Top model targets: Model Build Reason Status Build Duration ============================================================================================ ASAP2Demo Target (ASAP2Demo.c) did not exist. Code generated and compiled. 0h 0m 16.383s 2 of 2 models built (0 models already up to date) Build duration: 0h 0m 27.316s
Create and Explore ECU Descriptions
Create the ECU description object for the built model. Use the find function to list available computation methods.
descObj = coder.asap2.getEcuDescriptions("ASAP2Demo");Export duration: 0h 0m 0s 227ms
find(descObj, "CompuMethod")ans = 1×9 string
"CM_double" "CM_double_m_per_U0028_s_U005E_2_U0029" "CM_double_rpm" "CM_int16_rpm" "CM_int32" "CM_single" "CM_single_m_per_U0028_s_U005E_2_U0029" "CM_single_rpm" "CM_uint8"
Filter the computation methods to get only those that use rpm as the unit.
find(descObj, "CompuMethod", Units="rpm")
ans = 1×3 string
"CM_double_rpm" "CM_int16_rpm" "CM_single_rpm"
Add a Custom Computation Method
Create a computation method with a linear conversion type and add it to the ECU description object.
CompuMethod_1 = coder.asap2.CompuMethod; CompuMethod_1.Name = 'CompuMethod_1'; CompuMethod_1.ConversionType = "LINEAR"; CompuMethod_1.Coefficients = [2 3]; CompuMethod_1.LongIdentifier = "longIdentifierTest"; CompuMethod_1.Format = "%2.3"; CompuMethod_1.Units = "s"; add(descObj, CompuMethod_1);
Verify the properties of the newly added computation method.
get(descObj, "CompuMethod", "CompuMethod_1")
ans =
CompuMethod with properties:
Name: 'CompuMethod_1'
LongIdentifier: "longIdentifierTest"
Format: "%2.3"
Units: "s"
Coefficients: [2 3]
ConversionType: "LINEAR"
CompuVTabValues: [1×1 struct]
CustomData: ""
Update the conversion type to TAB_VERB and define the corresponding CompuVTabValues. Use the set function to modify properties of an existing description.
set(descObj, "CompuMethod", "CompuMethod_1", ConversionType="TAB_VERB"); set(descObj, "CompuMethod", "CompuMethod_1", CompuVTabValues=struct("Literals", ["false" "true"], "Values", [0 1]));
Verify the modified fields.
modifiedProp = get(descObj, "CompuMethod", "CompuMethod_1")
modifiedProp =
CompuMethod with properties:
Name: 'CompuMethod_1'
LongIdentifier: "longIdentifierTest"
Format: "%2.3"
Units: "s"
Coefficients: [2 3]
ConversionType: "TAB_VERB"
CompuVTabValues: [1×1 struct]
CustomData: ""
modifiedProp.CompuVTabValues
ans = struct with fields:
Literals: ["false" "true"]
Values: [0 1]
Add a Custom Characteristic
Create a characteristic that represents a calibration parameter and add it to the ECU description object. Then update its UpperLimit property.
param1 = coder.asap2.Characteristic; param1.Name = "Custom_parameter1"; param1.LongIdentifier = "longIdentifierParam"; param1.UpperLimit = 255; param1.LowerLimit = 0; add(descObj, param1); get(descObj, "Characteristic", "Custom_parameter1")
ans =
Characteristic with properties:
Name: "Custom_parameter1"
LongIdentifier: "longIdentifierParam"
Type: 'VALUE'
EcuAddress: '0x0000'
CompuMethodName: 'NO_COMPU_METHOD'
LowerLimit: 0
UpperLimit: 255
EcuAddressComment: ""
EcuAddressExtension: []
CalibrationAccess: 'Calibration'
DisplayIdentifier: ""
Format: ""
BitMask: []
AxisInfo: []
RecordLayout: ""
Dimensions: []
Export: 1
MaxRefresh: [1×1 struct]
SymbolLink: [1×1 struct]
CustomData: ""
set(descObj, "Characteristic", "Custom_parameter1", UpperLimit=128)
Add a Custom Measurement
Create a measurement that represents a signal and add it to the ECU description object. Then update its CalibrationAccess property.
signal1 = coder.asap2.Measurement; signal1.Name = "Custom_signal1"; signal1.LongIdentifier = "longIdentifierSignal"; signal1.UpperLimit = 255; signal1.LowerLimit = 0; add(descObj, signal1); get(descObj, "Measurement", "Custom_signal1")
ans =
Measurement with properties:
Name: "Custom_signal1"
LongIdentifier: "longIdentifierSignal"
DataType: 'UBYTE'
EcuAddress: '0x0000'
CompuMethodName: ""
LowerLimit: 0
UpperLimit: 255
Raster: [1×1 struct]
EcuAddressComment: ""
EcuAddressExtension: []
CalibrationAccess: 'NoCalibration'
DisplayIdentifier: ""
Format: ""
BitMask: []
Dimensions: []
Export: 1
MaskData: [1×1 struct]
MaxRefresh: [1×1 struct]
SymbolLink: [1×1 struct]
CustomData: ""
set(descObj, "Measurement", "Custom_signal1", CalibrationAccess="Calibration")
Add a Lookup Table Parameter
Create a lookup table parameter of type MAP with two axes. Each axis requires a name, computation method, maximum number of axis points, and axis type.
lutParam = coder.asap2.Characteristic; lutParam.Name = "custom_lookup_table"; lutParam.Type = "MAP"; axisData = coder.asap2.AxisInfo; axisData(1).Name = "BP3"; axisData(2).Name = "Bp4"; axisData(1).CompuMethodName = "ASAP2Demo_CM_double"; axisData(2).CompuMethodName = "ASAP2Demo_CM_double"; axisData(1).MaxAxisPoints = "3"; axisData(2).MaxAxisPoints = "3"; axisData(1).AxisType = "STD_AXIS"; axisData(2).AxisType = "STD_AXIS"; lutParam.AxisInfo = axisData; add(descObj, lutParam)
Export the Customized ASAP2 File
Export the ASAP2 file using the updated ECU description object. Verify that the generated file contains the custom computation method, characteristic, measurement, and lookup table parameter.
coder.asap2.export("ASAP2Demo", CustomEcuDescriptions=descObj);Remove Custom Descriptions
Remove the custom descriptions from the ECU description object.
delete(descObj, "CompuMethod", "CompuMethod_1"); delete(descObj, "Characteristic", "Custom_parameter1"); delete(descObj, "Measurement", "Custom_signal1");
Version History
Introduced in R2022b
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Seleziona un sito web
Seleziona un sito web per visualizzare contenuto tradotto dove disponibile e vedere eventi e offerte locali. In base alla tua area geografica, ti consigliamo di selezionare: .
Puoi anche selezionare un sito web dal seguente elenco:
Come ottenere le migliori prestazioni del sito
Per ottenere le migliori prestazioni del sito, seleziona il sito cinese (in cinese o in inglese). I siti MathWorks per gli altri paesi non sono ottimizzati per essere visitati dalla tua area geografica.
Americhe
- América Latina (Español)
- Canada (English)
- United States (English)
Europa
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)