Main Content

Average-Value Rectifier (Three-Phase)

Average-value three-phase AC voltage to DC voltage converter with fixed power loss

  • Library:
  • Simscape / Electrical / Semiconductors & Converters / Converters

  • Average-Value Rectifier (Three-Phase) block

Description

The Average-Value Rectifier (Three-Phase) block models an average-value, full-wave, six-pulse rectifier. It converts instantaneous three-phase AC voltages to DC voltage and DC power demand to three-phase AC power demand. The corresponding AC power demand is equal to the sum of the fixed power loss and the DC power demand.

You can use the Average-Value Rectifier (Three-Phase) block only as a six-pulse rectifier. You cannot combine two Average-Value Rectifier blocks to represent a twelve-pulse rectifier.

The figure shows the equivalent circuit for the rectifier as a full-wave, six-pulse rectifier. The Average-Value Rectifier (Three-Phase) block does not yield the harmonics that are typically associated with the detailed representation, however, because it performs an average-value power conversion.

Electrical Defining Equations

The voltages are defined by:

vref=va+vb+vc3,

VRMS=(vavb)2+(vbvc)2+(vcva)23,

vDC=32πVRMS,

vp=vref+vDC2,

and

vn=vrefvDC2,

where:

  • va, vb, vc are the respective AC phase voltages.

  • vref is the DC offset on the AC side. In a balanced AC power system with no DC bias, vDC is 0 V.

  • VRMS is the RMS AC line-line voltage.

  • vDC is the voltage difference between the positive and negative terminals of the rectifier.

  • 32/π is the vDC /VRMS ratio for a full-wave, six-pulse rectifier.

  • vp, vn are the voltages at the positive and negative terminals of the rectifier.

The resistance, power, and currents are defined by

Rfixed=VRated2Pfixed,

PDC=vpipvnin,

RAC=VRMS2PDC+VRMS2Rfixed,

and

[iaibic]=[vavbvc]vrefRAC,

where:

  • VRated is the rated AC voltage that you specify on the block mask.

  • Pfixed is the fixed power loss that you specify on the block mask.

  • Rfixed is the fixed per-phase series resistance in an equivalent wye-connected load.

  • ip, in are the currents flowing into the positive and negative terminals of the rectifier.

  • PDC is the power output on the DC side. PDC has a minimum limit of 0 W.

  • RAC is the per-phase series resistance in an equivalent wye-connected load.

  • ia, ib, ic are the respective AC phase currents flowing into the rectifier.

Ports

Conserving

expand all

Expandable three-phase port

Electrical conserving port associated with the positive terminal

Electrical conserving port associated with the negative terminal

Parameters

expand all

Rated voltage of the AC system.

Minimum power drawn on the AC side at rated AC voltage. When the instantaneous AC voltage is equal to the value you specify for the Rated AC voltage, the AC power demand equals the value you specify for the Fixed power loss plus DC power demand.

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Introduced in R2014b