NA-MAAB — a, b, c, d, e, f
JMAAB — a, b, c, d, e, f
All
Only these character types shall be used in structural subsystem names:
Single-byte alphanumeric characters (a-z
,
A-Z
, 0-9
)
Single-byte underscore (_
)
Line breaks, single-byte spaces, double-byte characters, and control characters shall not be used.
Not Applicable
Single-byte spaces, double-byte, and symbol characters are used.
A structural subsystem name shall not use numbers at the beginning.
Not Applicable
A structural subsystem name shall not use an underscore at the beginning.
Not Applicable
A structural subsystem name shall not use an underscore at the end.
Not Applicable
A structural subsystem name shall not use consecutive underscores.
Not Applicable
A structural subsystem shall not consist solely of a single reserved MATLAB® word.
Not Applicable
Sub IDs a, b, f:
Cannot generate code using the configured structural subsystem name.
Sub IDs c, d, e:
May not be able to generate code using the configured structural subsystem name.
Model Advisor check: Check Subsystem names (Simulink Check)
R2020a
JMAAB guideline jc_0201, which is available in Control Algorithm Modeling Guidelines Using MATLAB, Simulink, and Stateflow on the MathWorks® website.