Check usage of Discrete-Time Integrator block
Check ID:
mathworks.jmaab.jc_0627
Guideline: jc_0627: Usage of Discrete-Time Integrator blocks
Description
Checks use of the Discrete-Time Integrator block.
For Discrete-Time Integrator blocks, check if:
Block parameter Limit output is selected.
Saturation limits is defined using a
Simulink.Parameter
orMPT.Parameter
object whose data type isauto
.
This check requires a Simulink® Check™ license.
Check Parameterization
This check contains sub-checks that correspond to sub IDs specified in the JMAAB modeling guidelines. You can use the Model Advisor Configuration Editor to specify which sub IDs (one or multiple) to execute.
For reference, the guideline sub ID(s) that are recommended for use by the NA-MAAB and JMAAB modeling standards organizations are:
NA-MAAB — a
JMAAB — a, b
Results and Recommended Actions
Guideline Sub ID | Condition | Recommended Action |
---|---|---|
jc_0627_a: Check Saturation limit settings of Discrete-Time Integrator blocks | Block parameter Limit output is cleared. | Select the Discrete-Time Integrator block parameter Limit output. |
jc_0627_b: Check Saturation limit settings of Discrete-Time Integrator blocks | Saturation limit is defined by a Parameter object whose data type is
not auto . | Change the data type for the Parameter object to
auto . |
Capabilities and Limitations
Runs on library models.
Supports exclusions.
Analyzes content of library-linked blocks. By default, the input parameter Follow links is set to
on
.Analyzes content in masked subsystems. By default, the input parameter Look under masks is set to
graphical
.