Wye-Connected Variable Load
Three-phase variable load wired in wye configuration
Libraries:
Simscape /
Electrical /
Passive /
RLC Assemblies
Description
The Wye-Connected Variable Load block models a three-phase variable load wired in a wye configuration. Each limb of the load contains a resistor. The block calculates the resistance required to draw the real power of the physical signal input P at the rated voltage that you specify. Therefore, the block can represent a real load.
To ensure that the resistance is always greater than zero, you specify the minimum real power that the load consumes. The minimum real power must be greater than zero.
Equations
The resistance is defined by
where:
R is the per-phase series resistance.
VRated is the RMS, rated line-line voltage.
P is the three-phase real power required.
Ports
Input
Conserving
Parameters
Extended Capabilities
Version History
Introduced in R2014b