How to change simulink coverage settings in script?

Hi, how can I change for a model simulink coverage settings using script? some set, set_params, etc.? Thank you.

 Risposta accettata

The solution is:
set_param(gcs, 'CovHtmlReporting', 'off');
set_param(gcs, 'CovModelRefEnable', 'off');
set_param(gcs, 'CovExternalEMLEnable', 'off');

Più risposte (1)

I have not done this myself, but I recommend looking at the Use Coverage Commands in a Script documentation. The example illustrates how setupCmd is used on test objects to load settings using the command line.

1 Commento

there is a possibility to run cvtest with specific test options. but setting in the model remain the same. so user can run simulation only using the scripts, and not using simulink GUI.

Accedi per commentare.

Richiesto:

il 23 Apr 2014

Risposto:

il 2 Apr 2015