Why do I get a "Failed to navigate link" error when Navigate from a Simulink Object to a Requirement via the DOORs Surrogate Module
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
I was trying to Navigate from a Simulink Object to a Requirement via the Surrogate Module as detailed here: http://www.mathworks.com/help/slvnv/ug/navigate-with-the-surrogate-module.html#bsc_7fv-22
When trying the first step: "1.In the sf_car_doors model, right-click the transmission subsystem and select Requirements Traceability > 1. "DOORS Surrogate Item"
I get this error:
I can navigate from the Requirement to the Simulink Object, but not the other way around. What am I doing wrong?
0 Commenti
Risposte (1)
Artem
il 14 Nov 2014
This is a known bug, introduced in 14a and fixed in 14b.
To repair DOORS surrogate navigation in your installed MATLAB, put the attached file under toolbox/slvnv/reqmgt/+rmi/ directory.
Remove .p (and .m) files with matching name, restart MATLAB.