How can I set "Classical call interface" parameter using set_param?
7 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Here I use code generation scripts to automate the code generation, build and deployment pipeline. In one of the scripts I change my target programmatically using switchTarget , then Classical call interface goes off as default. How can I set it back to on using set_param?
0 Commenti
Risposta accettata
Eshwar
il 23 Gen 2015
You can try using
set_param(modelname,'GRTInterface','on')
There are some dependencies to be aware of for using the Classic Code Interface options (for example: C++ class code interface packaging sets this param off) which you can look up from the doc.
0 Commenti