Connect two blocks in a subsytem

2 visualizzazioni (ultimi 30 giorni)
Nedra Ebdelli
Nedra Ebdelli il 27 Mag 2015
Commentato: Vinay Sheshadri il 20 Ago 2016
I want to connect two blocks in a subsystem but i get this error: ??? Error using ==> in at 6 Invalid Simulink object name: Mtest/Subsystem/Logical Operator/1
My code is the following:
load_system('C:\Users\...\Desktop\Mtest')
add_line('Mtest','Mtest/Subsystem/Logical Operator/1','Mtest/Subsystem/Proof Objective4/1','autorouting','on')
save_system('Mtest')
Or my model contain block Logical Operator in ths Subsystem 'Subsystem'.

Risposte (1)

Nobel Mondal
Nobel Mondal il 27 Mag 2015
Hi Nedra,
I couldn't load the image you have attached. You could give this a try:
add_line('Mtest/Subsystem', 'Logical Operator/1', 'Proof Objective/1','autorouting','on')
Hope this helps.
Nobel.
  1 Commento
Nedra Ebdelli
Nedra Ebdelli il 27 Mag 2015
Modificato: Nedra Ebdelli il 27 Mag 2015
Hi Nobel,
Good ,it work .
Thank you
Nedra.

Accedi per commentare.