Force update scope window when running rapid accelerator mode from command line
7 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
As stated in Design Your Model for Effective Acceleration, Simulink does not allow the update of scope unless the rapid accelerator model is run from Simulink menu, for whatever reason. However, I am using a GUI to call the Simulink model and I wish to see real-time output using the scope, but the scopes won't update.
I wonder if there is a way to change this Simulink behaviour (this restriction really seems artificial to me). Alternatively, I wonder if there is a way to pretend (using command line code) that I am running the model from Simulink menu.
0 Commenti
Risposta accettata
TAB
il 5 Ott 2018
Modificato: TAB
il 5 Ott 2018
Scope will not update with sim command, but it works with SimulationCommand (please dont ask why :P)
set_param('MyModel', 'SimulationCommand', 'start')
SimulationCommand can take one of following value:
'start' | 'stop' | 'pause' | 'continue' | 'step' | 'update' | 'WriteDataLogs' | 'SimParamDialog' | 'connect' | 'disconnect' | 'WriteExtModeParamVect' | 'AccelBuild'
3 Commenti
TAB
il 5 Ott 2018
You can use get_param('mymodel', 'SimulationStatus') combined with while loop to wait for simulation to finish.