I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?
0 Commenti
Risposta accettata
Fangjun Jiang
il 9 Apr 2020
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
3 Commenti
Fangjun Jiang
il 20 Apr 2020
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.