When is the 'ModelRefe​renceVersi​onMismatch​Message' Simulink model parameter editable?

1 visualizzazione (ultimi 30 giorni)
When I open a model's test harness, I receive the following error:
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?

Risposta accettata

Fangjun Jiang
Fangjun Jiang il 9 Apr 2020
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
  3 Commenti
Fangjun Jiang
Fangjun Jiang il 20 Apr 2020
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.
Monika Jaskolka
Monika Jaskolka il 20 Apr 2020
Modificato: Monika Jaskolka il 20 Apr 2020
Thank you. You're right. I can enable the parameter by modifying the custom .tlc file like this:
slConfigUISetEnabled(hDlg, hSrc, 'ModelReferenceVersionMismatchMessage', 'true');

Accedi per commentare.

Più risposte (0)

Categorie

Scopri di più su Simulink Environment Customization in Help Center e File Exchange

Prodotti


Release

R2016b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by