respected sir
whenever i run matlab simulink the error shows Ambiguous sorted order detected due to use of triggered subsystem(s) in a loop. See Subsystem Examples in the Simulink library for valid and invalid examples of triggered subsystem please help me how to slove
0 Commenti
Risposte (1)
Remi
il 8 Mar 2016
I've experienced the same issue because the trigger signal depended on the output of the subsystem. If this was your problem, this can be solved by adding an unit delay to your output.
You can also refer to this thread http://www.mathworks.com/matlabcentral/answers/55428-how-can-i-use-a-triggered-subsystem-in-a-loop?s_tid=answers_rc1
1 Commento
Ali
il 23 Giu 2017
well I had the same error but in my case the output was dependent on the input, added a unit delay in the loop and everything fixed, thanks a lot :)