- Pat
Simulink Block not executed
11 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Ajay krishna Vasanthakumar
il 3 Giu 2020
Commentato: Ajay krishna Vasanthakumar
il 5 Giu 2020
Hey Guys,
i have a question ,Hope someone can answer it.
when the block is not executed in simulink(due to short circuit),the blocks recieves zero execution percentage.Does Simulink takes the number of the decision associated with the block which is not executed ,to calculate the overall decision percentage of the model?
Thanks
0 Commenti
Risposta accettata
Pat Canny
il 4 Giu 2020
Modificato: Pat Canny
il 4 Giu 2020
Hi Ajay,
The coverage report should show the decision coverage achieved for that block. I assume the block you are referring to, if it is able to receive Decision coverage, should also appear to not achieve any Decision coverage. Are you seeing that in the report?
The coverage report should also show the coverage achieved at the model level. If the block can receive Decision coverage, any missing Decision coverage from that block would reduce the overall model's Decision coverage.
Thanks.