Risposto
Create a repeating sequence without interpolation
There are three repeating sequence blocks in Simulink. With the right choice for Lookup Method, the block Repeating...

oltre un anno fa | 0

| accettato

Risposto
Simulink start takes long time to compile
If you have not done so already, I suggest you run Simulink Performance Advisor tool on your model. The Tool knows lots of grea...

oltre un anno fa | 0

Risposto
calling fi(var1, var2,..varN) in matlab function in a simulink model asks for constant values for input 2 to N
I don't know if there is or is not a way to make the MATLAB Function block recognize that W_HDISP as a constant at update diagra...

oltre un anno fa | 0

Risposto
Unit Delay block is supposed to be NOT a DIRECT FEEDTHROUGH But in documentation it is said YES
The Delay Block and the Unit Delay Block are subtly complicated especially with regard to Direct Feedthrough. Whether or not Di...

oltre un anno fa | 1

| accettato

Risposto
How to remain the bits of input signal port unchanged after using fixed-point tool?
LockScale prevents changes by Fixed-Point Tool Often some signals and parameters in a model are mandated early in the design pr...

oltre un anno fa | 0

| accettato

Risposto
Is it possible to disable compiling before simulating in Simulink?
Simulink Fast Restart is exactly what you want (assuming you are not making structural changes to your model between simulations...

oltre un anno fa | 2

| accettato

Risposto
Nonlinear plant in simulink
The key is to model Y(k+1) to Y(k) using a unit delay. The output of the unit delay is the input value from one time step earl...

oltre un anno fa | 0

Risposto
Mask parameter value is ignored with HDL Counter word length
Model Reference is not compatible with what you are trying to do. As an alternative, consider creating a Simulink library and pu...

oltre un anno fa | 1

| accettato

Risposto
help required for fixed point conversion
Mapping an A2D to a fixed-point data type One way to map an A2D converter to a fixed-point data type is to use two real-world-v...

oltre un anno fa | 0

| accettato

Risposto
help required for fixed point conversion
The number 395 is how many times that block in the model overflowed during the previous simulation. Suppose the element was a da...

oltre un anno fa | 0

Risposto
help required for fixed point conversion
Hi Gary, That portion of your model will involve 4 data types. Digital measurement of output signal from analog plant Set poi...

oltre un anno fa | 0

Risposto
Overflows when I use Fixed-Point Tool
Two Kinds of Overflows Fixed-Point Tool presents two types of overflows, Actual and Potential. Actual Overflows Actual overfl...

oltre un anno fa | 0

| accettato

Risposto
Problem with Simulink.NumericType after AUTOSAR-XML (ARXML) import
To simulate the model with the fixed-point data types and see bit-true behavior will require a Fixed-Point Designer license. Ho...

oltre un anno fa | 0

Risposto
Can we replace parameter value with parameter name while generating C code from model?
Please see the documentation Macro Definitions (#define) - MATLAB & Simulink (mathworks.com)

oltre un anno fa | 0

Risposto
Am I missing something, or is the Tip wrong?
Hi, The advise is generally correct. Turning off Integer Saturation and allowing the math to wrap modulo 2^N will lead to lea...

oltre un anno fa | 1

| accettato

Risposto
Why is my Simulink data type randomly changing?
Yes, this is most likely due to attribute propagation. You likely have an underspecified "chicken and egg loop" in your model. T...

oltre un anno fa | 1

| accettato

Risposto
What is the efficient code?
Simple Ansewer: Use shift approach unless multiplicative constant is really big In my experience, the multiply by constant foll...

oltre un anno fa | 0

Risposto
Method of Real number multiplication operation
Quick Answer: Shifts are Multiply or Divide by a Power of Two Shift left of M bits is equivalent to multiplication by 2^M wh...

oltre un anno fa | 0

| accettato

Risposto
Trouble using fixed point type conversion in Simulink
Check rounding and overflow handling mode By default, the Data Type Conversion block rounds to Floor and Wraps overflows. In c...

oltre un anno fa | 0

| accettato

Risposto
What is the "net slope"
Net slope is used in fixed-point operations to achieve agreement of scaling. The slopes of all the variables involved in an oper...

oltre un anno fa | 0

| accettato

Risposto
Simulink model converts floating-point numbers to fixed-point numbers
Suggestion consider using modByConstant Since the "denominator" of your modulos are constants, you my wish to use the modByCons...

oltre un anno fa | 0

Risposto
Simulink model converts floating-point numbers to fixed-point numbers
By default zeros() gives double Your output is double because of how it is initialized with the zeros() function n = 3; m = 4...

oltre un anno fa | 0

| accettato

Risposto
Data type conversion changes the value of the signal
Why cast to single has large quantization error. The cast from fixed-point to single will use single precision for constants an...

quasi 2 anni fa | 0

| accettato

Risposto
Data type conversion changes the value of the signal
Brief answer The original value 0.1 is between two representable values (0.099609375 and 0.1005859375) of the type being quanti...

quasi 2 anni fa | 0

Risposto
Time delay threshold for constant output
I suggest you start by writing down on paper the equations or pseudo code that you think will solve the requirements of your pro...

quasi 2 anni fa | 0

Risposto
Error in Divide Block - System Generator
The System Generator is a Simulink add-on product developed by AMD (Xilinx). The data types mentioned in the error message, Fix...

quasi 2 anni fa | 0

| accettato

Risposto
Remainder of a division operation in System Generator
Consider restructuring your design to work in units of revolutions instead of in degrees. In that case you only need to perform ...

quasi 2 anni fa | 0

| accettato

Risposto
Simulink Moving Average block not averaging according to the window length specified
Hi Shani, Please create a simplified model that exercises the Moving Average Block in isolation. Create a test input sequence...

quasi 2 anni fa | 0

Risposto
Floating-Point to Fixed-Point Conversion of IIR Filters
Hi, Examples often depend on supporting files. To successfully run these examples, all the files needed by the example need to ...

quasi 2 anni fa | 0

Risposto
FAQ: Why does a value look more precise when displayed in MATLAB or Simulink than in the generated code?
Textual Representation is Often an Approximation The textual representation of values displayed in MATLAB and Simulink is ofte...

quasi 2 anni fa | 1

| accettato

Carica altro