Main Content

Control Views in the Fixed-Point Tool

The following sections describe how to control the amount of information that is shown in the Fixed-Point Tool. Within the Fixed-Point Tool, you can filter the results that are displayed at a given time by run, or by the subsystem in which the result belongs. You can also add or remove the columns that are shown in the spreadsheet of the Fixed-Point Tool.

Filter Results by Run

In the Fixed-Point Tool, each time you collect ranges, either through simulation or derived range analysis, or run an embedded simulation, the tool stores the collected information in a run. Using the Workflow Browser, you can filter the results shown in the spreadsheet. Select the runs that you want to view in the spreadsheet.

Workflow Browser pane in the Fixed-Point Tool with the Embedded run selected.

Filter Results by Subsystem

By default, the Fixed-Point Tool displays only the results for model objects in your specified system under design. To filter the results shown or to see additional results, you can select a different node in the model hierarchy pane. The spreadsheet displays all model objects at and below the selected node.

Model Hierarchy pane in the Fixed-Point Tool with the Controller Subsystem node selected.

To view the data objects specified in your model, click the Data Objects node in the tree.

Control Column Views

As you follow the workflow for converting your model to fixed point using the Fixed-Point Tool, the tool displays the spreadsheet columns that are most pertinent to your current step in the workflow. If you want to view additional columns, you can add them to the spreadsheet by right-clicking any of the existing column headers.

Menu listing columns that can be displayed in the spreadsheet. Items with the checkbox selected are displayed in the spreadsheet.

You can sort the results in the spreadsheet by clicking the header of the column on which you want to sort.

Use the Explore Tab to Sort and Filter Results

Using the Explore tab of the Fixed-Point Tool, you can sort and filter results in the tool based on additional criteria. The Explore tab is available whenever a single run that contains visualization data is selected in the Run Browser of the Fixed-Point Tool.

Explore toolstrip in the Fixed-Point Tool. Toolstrip buttons let you sort and filter the results

When there are unapplied proposals in the Fixed-Point Tool, the tool sorts and filters based on the ProposedDT. If there are no unapplied proposals, the tool sorts and filters the results based on the SpecifiedDT. If there is no SpecifiedDT available, for example if the result specifies an inherited data type, then the tool uses the CompiledDT.

Sort

You can sort results based on the following criteria.

Sorting CriteriaDescription

Execution Order

Order in which the blocks are executed during simulation

Magnitude

The larger of the absolute values of the SimMin and SimMax

Dynamic Range

Difference between the value representable by the largest bin and smallest bin in the histogram of logged values

Word Length

Total number of bits in the data type

Integer Length

Number of bits devoted to representing integer values in the data type

The tool calculates the integer length as word length fraction length. For example, for the data type fixdt(1,16,12), the tool calculates the integer length as 4. The data type fixdt(1,16,-16) would have a calculated integer length of 32.

Fraction Length

Number of bits in the fractional part of the data type

By default, the tool sorts in ascending order. To have the tool sort in descending order, select Descending. You can select only one sorting criteria at a time.

Filter

You can filter results based on the following criteria.

Filter CriteriaSelections
Data Types
  • Fixed-Point

  • Double

  • Single

  • Half

  • Boolean

  • Base Integer

Numerical Issues
  • Overflow - Show only results containing an overflow

  • Underflow - Show only results containing an underflow

  • None - Show only results containing no underflows or overflows

Number Space
  • Integer - Show only results for which the logged values are always integers.

  • Fraction - Show results for which the logged values contain a fractional part.

Signedness
  • Signed - Show only results for which the data type can represent signed values. For example, int16, fixdt(1,16,12), and floating-point data types.

  • Unsigned - Show only results for which the data type can represent only unsigned values. For example, uint16, Boolean, fixdt(0,16,12)

You can select multiple filtering selections from a criteria category by holding the Ctrl key while you select additional selections. When you select multiple filtering selections from the same criteria category, they are combined using OR logic. When you select multiple filtering selections across different criteria categories, they are combined using AND logic.

You can clear a selection by holding the Ctrl key. To clear all filters, click the Clear Filter button.

Related Topics