"rt" prefix for identifiers
Diagnostic action to take during code generation if parameter, block, or signal name begins with rt
Model Configuration Pane: Diagnostics / Data Validity
Description
The "rt" prefix for identifiers parameter specifies the diagnostic action
to take during code generation if the name of a Simulink® object, such as a parameter, block, or signal,
begins with rt. By default, the software
issues an error during code generation to prevent clashes with
generated identifiers that begin with
rt.
Settings
error (default) | warning | noneerrorThe software issues an error and terminates code generation if the name of a Simulink object begins with
rt.warningThe software issues a warning during code generation if the name of a Simulink object begins with
rt.noneThe software does not issue a diagnostic during code generation if the name of a Simulink object start with
rt.
Recommended Settings
| Application | Setting |
|---|---|
| Debugging | No impact |
| Traceability | No impact |
| Efficiency | No impact |
| Safety precaution | error |
Programmatic Use
Parameter: RTPrefix |
| Type: string | character vector |
Value: "none" | "warning" | "error" |
Default: "error" |
Version History
Introduced in R2006a