jc_0806: Detecting incorrect calculation results
Guideline Publication
Control Algorithm Modeling Guidelines - Using MATLAB®, Simulink®, and Stateflow®
Sub ID Recommendations
- NA-MAAB — a, b, c 
- JMAAB — a, b, c 
MATLAB Versions
All
Rule
Sub ID a
Configuration parameter Division by singular matrix
                shall be set to Error.
Custom Parameter
Not Applicable
Sub ID b
Configuration parameter Inf or NaN block output shall
                be set to Error.
Custom Parameter
Not Applicable
Sub ID c
(R2014b and later) These configuration parameters shall be set to
                    Error: 
(R2010b to R2014a) Configuration parameter Detect
                    overflow shall be set to Error.
Custom Parameter
Not Applicable
Rationale
Sub IDs a, b, c:
- Allows detection of operations with invalid values. 
Verification
Model Advisor check: Check diagnostic settings for incorrect calculation results (Simulink Check)
Last Changed
R2020a
Version History
Introduced in R2020a