Main Content
Check safety-related diagnostic settings that apply to function-call connectivity
Check ID:
mathworks.hism.hisl_0308
Check model configuration for diagnostic settings that apply to function-call connectivity and that can impact safety.
Description
This check verifies that model diagnostic configuration parameters pertaining to function-call connectivity are set optimally for generating code for a safety-related application.
Available with Simulink® Check™.
Results and Recommended Actions
Condition | Recommended Action |
---|---|
The diagnostic that specifies whether the Simulink software has to compute inputs of a function-call
subsystem directly or indirectly while executing the subsystem is set to
Use local settings or
Disable
all . This
diagnostic detects unpredictable data coupling between a function-call
subsystem and the inputs of the subsystem in the generated code. | Set Context-dependent inputs on the Diagnostics > Connectivity pane in the Configuration Parameters dialog box or set the
parameter FcnCallInpInsideContextMsg to
error . |
Action Results
Clicking Modify Settings configures model diagnostic settings that apply to function-call connectivity and that can impact safety.
Capabilities and Limitations
Does not run on library models.
Does not allow exclusions of blocks or charts.