Main Content

removeOpening

Remove opening from list of permanent loop openings in slLinearizer or slTuner interface

Description

removeOpening(s,op) removes the specified opening, op, from the list of permanent openings for the slLinearizer or slTuner interface, s. You can specify op to remove either a single or multiple openings.

removeOpening does not modify the model associated with s.

example

Examples

collapse all

Create an slLinearizer interface for the scdcascade model.

sllin = slLinearizer('scdcascade');

Generally, you configure the interface with analysis points, openings, operating points, and parameter values. For this example, add only openings to the interface.

addOpening(sllin,{'y2m','y1m','u1'});

'y2m', 'y1m', and 'u1' are the names of signals in the scdcascade model. The addOpening command adds these signals to the list of permanent openings for sllin.

Remove the 'y1m' opening from sllin.

removeOpening(sllin,'y1m');

Create an slLinearizer interface for the scdcascade model.

sllin = slLinearizer('scdcascade');

Generally, you configure the interface with analysis points, openings, operating points, and parameter values. For this example, add only openings to the interface.

addOpening(sllin,{'y2m','y1m','u1'});

'y2m', 'y1m', and 'u1' are the names of signals in the scdcascade model. The addOpening command adds these signals to the list of permanent openings for sllin.

Remove the 'y1m' and 'y2m' openings from sllin.

removeOpening(sllin,{'y1m','y2m'});

Create an slLinearizer interface for the scdcascade model.

sllin = slLinearizer('scdcascade');

Generally, you configure the interface with analysis points, loop openings, operating points, and parameter values. For this example, add only openings to the interface.

addOpening(sllin,{'y2m','y1m','u1'});

'y2m', 'y1m', and 'u1' are the names of signals in the scdcascade model. The addOpening command adds these signals to the list of permanent openings for sllin.

Determine the index number of the opening you want to remove. To do this, display the contents of the interface, which includes opening index numbers, in the Command Window.

For this example, remove the 'y1m' opening from sllin.

sllin
 
slLinearizer linearization interface for "scdcascade":

No analysis points. Use the addPoint command to add new points.
3 Permanent openings: 
--------------------------
Opening 1:
- Block: scdcascade/Sum3
- Port: 1
- Signal Name: y2m
Opening 2:
- Block: scdcascade/Sum
- Port: 1
- Signal Name: y1m
Opening 3:
- Block: scdcascade/C1
- Port: 1
- Signal Name: u1
 
Properties with dot notation get/set access:
      Parameters         : [] 
      OperatingPoints    : [] (model initial condition will be used.)
      BlockSubstitutions : []
      Options            : [1x1 linearize.LinearizeOptions]

The displays shows that 'y1m' is the second opening of sllin.

Remove the opening from the interface.

removeOpening(sllin,2);

Create an slLinearizer interface for the scdcascade model.

sllin = slLinearizer('scdcascade');

Generally, you configure the interface with analysis points, openings, operating points, and parameter values. For this example, add only openings to the interface.

addOpening(sllin,{'y2m','y1m','u1'});

'y2m', 'y1m', and 'u1' are the names of signals in the scdcascade model. The addOpening command adds these signals to the list of permanent openings for sllin.

Determine the index numbers of the openings you want to remove. To do this, display the contents of the interface, which includes opening index numbers, in the Command Window.

For this example, remove the 'y2m' and 'y1m' openings from sllin.

sllin
 
slLinearizer linearization interface for "scdcascade":

No analysis points. Use the addPoint command to add new points.
3 Permanent openings: 
--------------------------
Opening 1:
- Block: scdcascade/Sum3
- Port: 1
- Signal Name: y2m
Opening 2:
- Block: scdcascade/Sum
- Port: 1
- Signal Name: y1m
Opening 3:
- Block: scdcascade/C1
- Port: 1
- Signal Name: u1
 
Properties with dot notation get/set access:
      Parameters         : [] 
      OperatingPoints    : [] (model initial condition will be used.)
      BlockSubstitutions : []
      Options            : [1x1 linearize.LinearizeOptions]

The displays shows that 'y2m' and 'y1m' are the first and second openings of sllin.

Remove the openings from the interface.

removeOpening(sllin,[1 2]);

Input Arguments

collapse all

Interface to a Simulink model, specified as either an slLinearizer interface or an slTuner interface.

Opening to remove from the list of permanent openings for s, specified as:

  • Character vector or string — Opening signal name.

    To determine the signal name associated with an opening, type s. The software displays the contents of s in the MATLAB® command window, including the opening signal names, block names, and port numbers. Suppose an opening does not have a signal name, but only a block name and port number. You can specify op as the block name.

    You can specify op as a uniquely matching portion of the full signal name or block name. Suppose the full signal name of an opening is 'LoadTorque'. You can specify op as 'Torque' as long as 'Torque' is not a portion of the signal name for any other opening of s.

    For example, op = 'y1m'.

  • Cell array of character vectors or string array — Specifies multiple opening names. For example, op = {'y1m','y2m'}.

  • Positive integer — Opening index.

    To determine the index of an opening, type s. The software displays the contents of s in the MATLAB command window, including the opening indices. For example, op = 1.

  • Vector of positive integers — Specifies multiple opening indices. For example, op = [1 2].

More About

collapse all

Version History