Virtual Reference Feedback Tuning
Automatically tune linearly parameterized controllers based on input-output data
Since R2025a
Libraries:
Simulink Control Design /
Autotuning
Description
Virtual reference feedback tuning (VRFT) is a direct data-driven control technique that allows you to tune linearly parameterized controllers based on the plant input and output data. You can use the Virtual Reference Feedback Tuning block to implement VRFT. The major benefits of the Virtual Reference Feedback Tuning block include the ability to perform one-shot tuning, requiring only a single experiment; suitability for tuning linear combinations of linear control laws, including PID and FIR; and support for both online and offline workflows. Using this block, you can tune a controller parameterized in one of the following forms:
PID Controller — Tune parallel-form PID controllers.
Here, α(z) is the discrete-time integrator formula.
FIR Filter — Tune FIR Filter.
Generic Form — Tune a generic-from controller. This can represent a combination of linearly parameterized controllers.
For more information about VRFT, see Virtual Reference Feedback Tuning.
Examples
Tune PID Controller for Mass-Spring-Damper System Using Virtual Reference Feedback Tuning Block
Tune PID controller for mass-spring-damper using VRFT.
- Since R2025a
- Open Live Script
Tune FIR Filter Type Controller for Flexible Transmission System Using Virtual Reference Feedback Tuning Block
Tune FIR filter type controller using VRFT.
- Since R2025a
- Open Live Script
Tune PID Controller for Vehicle Lateral Control System Using Virtual Reference Feedback Tuning Block
Use the Virtual Reference Feedback Tuning block to tune PID controller for a vehicle lateral control system.
- Since R2025a
- Open Live Script
Ports
Input
Provide the plant input signal data at this port. For this block, you can provide input-output data either during the simulation (online tuning) or as pre-logged data (offline tuning).
Provide the plant output signal data at this port. For this block, you can provide input-output data either during the simulation (online tuning) or as pre-logged data (offline tuning).
To start and stop the tuning process, provide a signal at the start/stop port. When the value of the signal changes from:
Negative or zero to positive, the tuning starts
Positive to negative or zero, the signal generation stops
Typically, you can use a signal that changes from 0 to 1 to start the tuning, and from 1 to 0 to stop it. You can also use the Start-Stop Generator block to generate this signal.
Generate a tuning interval signal which is long enough for the algorithm to collect sufficient data such that all θ values converge.
Output
Tuned controller parameters, returned as an n-by-1 vector signal, where n is the number of controller parameters.
Parameters
To edit block parameters interactively, use the Property Inspector. From the Simulink® Toolstrip, on the Simulation tab, in the Prepare gallery, select Property Inspector.
Sample time of the block, specified as a positive scalar. The block uses this value to sample the input-output data. This value must match the sample time of the controller you are tuning.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | DiscreteTs |
| Values: | "0.1" (default) | positive scalar in quotes |
Example: set_param(gcb,"DiscreteTs","0.5")
Reference model, specified as a tf, ss,
or zpk object. The reference model describes the desired
closed loop behavior of the system from reference
r(t) to output
y(t). For this parameter, you can
either provide a continuous-time or discrete-time model as an input. When
the input is a continuous-time model, the block discretizes the model using
Tustin discretization. When you want to provide a discrete-time model, the
sample time must match the Sample Time parameter
value.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | MrefS |
| Values: | "tf(1,[3 1])" (default) | tf, ss, or
zpk model object in quotes |
Example: set_param(gcb,"MrefS","zpk([],-3,3)")
Weighting function, specified as a tf,
ss, or zpk object. You can use this
parameter to emphasize particular frequencies where matching the
r(t)-to-y(t)
transfer function with the reference model is most important.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | WeightS |
| Values: | "1" (default) | tf, ss, or
zpk model object in quotes |
Example: set_param(gcb,"WeightS","tf([0.1 3],[1
0.03])")
Controller structure to tune, specified as one of the following:
PID Controller — Tune parallel-form PID controllers.
Here, α(z) is the discrete-time integrator formula.
FIR Filter — Tune FIR Filter.
Generic Form — Tune a generic-from controller. This can represent a combination of linearly parameterized controllers.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | ControlType |
| Values: | "PID" (default) | "FIR Filter" | "Generic Form" |
Example: set_param(gcb,"ControlType","Generic
Form")
Specify which of the proportional, integral, and derivative terms are in the controller.
P— Proportional action only.I— Integral action only.PI— Proportional and integral action only.PD— Proportional and derivative action only.PID— Proportional, integral, and derivative action.
Dependencies
To enable this parameter, set Controller Structure to PID.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | PIDControlType |
| Values: | "PI" (default) | "P" | "I" | "PD" | "PID" |
Example: set_param(gcb,"PIDControlType","PID")
Discrete integrator formula α(z) for integration in discrete-time PID controller:
Specify Integrator Method as one of the following:
Forward Euler— .Backward Euler— .Trapezoidal— .
For more information about discrete-time integration, see the Discrete-Time Integrator block reference page.
Dependencies
To enable this parameter, set Controller Structure to PID and set Type to a controller type with integral action.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | PIDIntegratorMethod |
| Values: | "Forward Euler" (default) | "Backward Euler" | "Trapezoidal" |
Example: set_param(gcb,"PIDIntegratorMethod","Trapezoidal")
Order of the FIR filter to tune, specified as a positive integer between 2 and 10.
Dependencies
To enable this parameter, set Controller Structure to FIR Filter.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | FIRFilterOrder |
| Values: | "2" (default) | positive integer between 2 and 10 in quotes |
Example: set_param(gcb,"FIRFilterOrder","5")
Linear systems
Ci(z) in
the generic-form control structure, specified as a cell array of LTI objects
(ss, tf, zpk) or an
LTI model array.
Specify this parameter such that the value matches the form of the controller to tune. This can also represent a combination of linearly parameterized controllers. Here, the controller parameters θi are ordered corresponding to the index of LTI objects provided in the array. For example, the default value of this parameter represents a discrete-time parallel-form PID controller, with θ1 as the proportional gain and θ2 as the integral gain.
Dependencies
To enable this parameter, set Controller Structure to Generic Form.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | LTIInputObj |
| Values: | "{tf([1],[1],0.1);0.1*tf([1],[1
-1],0.1)}" (default) | cell array in quotes | LTI model array in quotes |
Example: set_param(gcb,"LTIInputObj","{tf([1],[1],0.1);(1/0.1)*tf([1
-1],[1 0],0.1)}")
Enable this option to output the transient values of θ at the block output port θ when tuning.
Programmatic Use
To set the block parameter value programmatically, use
the set_param function.
| Parameter: | ShowThetaWhileTuning |
| Values: | "on" (default) | "off" |
Example: set_param(gcb,"ShowThetaWhileTuning","off")
Extended Capabilities
C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.
Version History
Introduced in R2025a
See Also
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Seleziona un sito web
Seleziona un sito web per visualizzare contenuto tradotto dove disponibile e vedere eventi e offerte locali. In base alla tua area geografica, ti consigliamo di selezionare: .
Puoi anche selezionare un sito web dal seguente elenco:
Come ottenere le migliori prestazioni del sito
Per ottenere le migliori prestazioni del sito, seleziona il sito cinese (in cinese o in inglese). I siti MathWorks per gli altri paesi non sono ottimizzati per essere visitati dalla tua area geografica.
Americhe
- América Latina (Español)
- Canada (English)
- United States (English)
Europa
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)