Problem with connection
Mostra commenti meno recenti
Hi... I create a model but appear the next error:
"The following two blocks cannot be connected in series because they are modeled as current sources:
Block 1: Ideal Switch1 Block 2: Subsystem/Controlled Current Source
Add a high-value resistance in parallel with one of the two block. You can also specify high-value resistive snubbers if the blocks have a snubber device."
The Ideal Switch1 and the Subsystem/Controlled Current Source was SimPowerSystems but what resistor i use to correct the error?
1 Commento
Kaustubha Govind
il 27 Giu 2011
I don't have any experience with SimPowerSystems but you could possibly set a large value for the "Snubber resistance Rs" parameter in the Ideal Switch dialog, as the error message suggests.
Risposta accettata
Più risposte (3)
Arnaud Miege
il 28 Giu 2011
3 voti
Just use a Series RLC Branch in parallel with your ideal switch, but keep everything on the SimPowerSystems side (i.e. the resistor should between ports 1 & 2 of the ideal switch).
HTH,
Arnaud
1 Commento
Nuno
il 30 Giu 2011
Nuno
il 26 Giu 2011
0 voti
Nuno
il 28 Giu 2011
0 voti
Categorie
Scopri di più su Power Converters in Centro assistenza e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!