Reg. PDEPE 's internal discretization of time
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
Harry
il 4 Mag 2014
Commentato: assionvi hove kouevi
il 12 Mag 2017
Hello, I am solving a reaction diffusion equation where there is a radiation term. Now the radiation is given once per day let's say instantaneously. But instead of modelling this instantaneous radiation I took time step to be one day. And modelling the radiation only as a function of space(or x). So I would expect this radiation term to be counted only once and would be equivalent to instantaneous radiation. But I came to know from someone that while solving the problem pdepe might be discretizing time in it's own way during the simulation. Is this so? If this is so then I am in trouble since the radiation term would no longer be counted only once and I would end up giving an overdose. Can someone please shed some light on how pdepe discretizes time internally over and above the discretization I specify? Thanks
0 Commenti
Risposta accettata
Bill Greene
il 4 Mag 2014
pdepe uses the variable time step ODE solver, ode15s, internally.
The time step size is automatically chosen by ode15s to obtain a prescribed accuracy.
The time discretization that you specify to the pdepe function is only to tell ode15s the points in time where you would like output.
Bill
1 Commento
assionvi hove kouevi
il 12 Mag 2017
Hi Bill,
Is there a way to extract the PDEPE 's internal discretization of time for a given maximum time step?
thanks.
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Partial Differential Equation Toolbox in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!