Specific data pump has a flow rate of 168 m³ / h, speed of 2950 r / min, head of 260 m, the inlet pressure of 0.25 MPa, outlet pressure of 2.3 MPa. How to set parameters in the centrifugal pump module ~
泵的具体数据有流量为168 m³/h,转速为2950 r/min,扬程为260 m,入口压力为0.25 MPa,出口压力为2.3 MPa。怎么在泵模块中设置参数~最好是离心泵模块~

Risposte (1)

noman shah
noman shah il 8 Dic 2015
use the data in 2D tabular form in the pump dialog box.
use [168/3600;168/3600] in the pump delivery vector and select unit m3/s
the pressure difference across pump you have to enter in the parameter is [2.3e6-0.25e6;2.3e6-0.25e6]