Sample time setting for high frequency systems
Mostra commenti meno recenti
What sample time should I use when simulating a system operating at 100 kHz?
It seems to me that the typical 0.2 seconds would be to small.
Are there quidelines for determining the appropriate sample time?
Risposte (2)
Fangjun Jiang
il 15 Ago 2011
0 voti
A 100kHz signal means its period is 10us. If the signal is a sine wave, you would need about 20 data points to represent a complete cycle of a sine wave with good quality. That means 0.5us is your maximum step size or sample time. 0.2 seconds is way bigger.
Stephen
il 15 Ago 2011
0 voti
1 Commento
Fangjun Jiang
il 15 Ago 2011
Sure. The proper sample time should be determined by the need of the application. To measure the noise level and temperature of a living room, for example, could have quite different sample time.