Fangjun Jiang - MATLAB Central
photo

Fangjun Jiang


Last seen: Today Attivo dal 2011

Followers: 3   Following: 0

Messaggio

What is a model? Professional Interests: Model-Based Development

Programming Languages:
MATLAB
Spoken Languages:
English
Pronouns:
He/him

Statistica

All
MATLAB AnswersCodyFrom 01/11 to 03/25Use left and right arrows to move selectionFrom 01/11Use left and right arrows to move left selectionTo 03/25Use left and right arrows to move right selectionUse TAB to select grip buttons or left and right arrows to change selection100%

RANK
24
of 297.457

REPUTAZIONE
10.300

CONTRIBUTI
14 Domande
4.070 Risposte

ACCETTAZIONE DELLE RISPOSTE
71.43%

VOTI RICEVUTI
1.556

  • Master
  • 36 Month Streak
  • Revival Level 3
  • First Review
  • Thankful Level 3
  • Knowledgeable Level 5
  • First Answer
  • Solver

Visualizza badge

Feeds

Visto da

Risposto
Fliping Mux in Matlab code
set_param(BlockPath,'Orientation','left')

1 giorno fa | 0

| accettato

Risposto
check Matlab tlbxs availabe and license
featureStr={'MATLAB','Simulink'} index = cellfun(@(f) license('test', f), featureStr) availableFeatures = featureStr(logical(i...

4 giorni fa | 0

Risposto
Branched Merge Block Check - How do I prevent this warning ?
Do you have cascaded Merge blocks? Do any of the incoming signals to Merge1 and Merge2 come from a Merge block? Or the output of...

4 giorni fa | 0

Risposto
Matlab function in Simulink exhibiting slow reaction time
I must know this. 1700 seconds is roughly 1/50 of the simulation time (24 hours). It is the default setting. It must mean that y...

5 giorni fa | 0

| accettato

Risposto
How to make custom library in Simulink available to other users and in different versions?
If you have a newer version of MATLAB (e.g. R24b), you can save/export a Simulink model or library as older version (e.g. R23b),...

7 giorni fa | 0

Risposto
how can I array the external inputs for code generation in Simulink embedded coder?
For the array case, you just need to specify the size of that Inport block. Keep in mind that you can't comibne multiple inputs ...

7 giorni fa | 0

Risposto
Table.Properties.VariableNames will add ... to long Variable Names
I think the OP was referring to the three dots in the image in the header row. It is a display, @Alexander Szambor. If you drag...

10 giorni fa | 1

Risposto
How to call columns from table when heading names are variable dependent
use data.(MaxColumn). This is similar to dynamic field names like below. a.FirstColumn=1; ColumnName='FirstColumn' a.(ColumnN...

13 giorni fa | 0

| accettato

Risposto
I am getting error for configurable subsystem in R2024b
"Configurable subsystem" is in pretty old versions of Simulink. It sounds like that in R2024b, it is definitely no longer suppor...

19 giorni fa | 1

Risposto
How to read out value from simout object
You need to click that signal line, right click, select properties, and then give it a name and log the signal. Once done that, ...

19 giorni fa | 0

Risposto
Delay - bus as initial condition and bus propagation
I am intested in this question so I made an example. According to the document, 'The initial condition x0 port accepts nonvirtu...

20 giorni fa | 0

Risposto
Simulation manager with initFcn
'InitFcn' is executed before the simulation starts, that is probably the reason that your parameter values set in the multiple s...

20 giorni fa | 0

Risposto
What is the Matlab code that connects a variable to a Slider Switch Block?
The 'binding' needs to be a block in the model. If that block uses 'A' as a parameter and that parameter is selected to be bound...

25 giorni fa | 1

Risposto
[Linux] Error in MatlabWindow after upgrading Ubuntu from 20.04 to 22.04
According to this, up to Ubuntu 18.04 LTS is supported by MATLAB R2018b. https://www.mathworks.com/content/dam/mathworks/mathwo...

25 giorni fa | 0

Risposto
Force default datatype to single in undefined Simulink blocks
'DefaultUnderspecifiedDataType' is not the same as 'Default DataType'. Your setting only applies to the Constant block because i...

27 giorni fa | 0

| accettato

Risposto
How do I get the relative error between 2 signals in Simulink?
Assume x and y are the two signals, you are doing abs((x-y)/x) or abs((x-y)/y), when x or y is close to zero, it will cause di...

27 giorni fa | 1

| accettato

Risposto
Tally Instances of Negative Numbers in an Array (for loop)
A=load() returns A as a structure, not a typical matrix. If you make A an matrix, this code would work if you make the following...

28 giorni fa | 0

Risposto
isnan to conver nan to zero in a table
T is an object of the class "table". You can't apply isnan() on it directly. Try the 'TreatAsMissing' option of the readtable() ...

29 giorni fa | 0

Risposto
Is there a way to extract a list from "PV Array.ModuleName.Enum" to view the solar module data more efficiently?
Should be BlockDialogParameters.ModuleName.Enum or getfield(BlockDialogParameters.ModuleName,'Enum')

29 giorni fa | 0

Risposto
Plot RGB triplets from a matrix as markers 'o'
Use 'color' to specify color in plot() x = linspace(0,10,10); y = linspace(0,10,10); xlabel('X-axis'); ylabel('Y-axis'); ax...

circa un mese fa | 0

Risposto
What is the max number of digits allowed for a base 2 number?
The default data type in MATLAB is "double", which means 64 bits. When used to represent a base 2 number, its maximum value is 2...

circa un mese fa | 0

Risposto
How to set Simulink block parameters using an absolute model path
The "absolute model path" of a block starts with the name of the model, not including the file folder where the model file is st...

circa un mese fa | 0

| accettato

Risposto
How to output text to Command Window if signal changes from 0 to 1 in Simulink
You might want to do that, but MATLAB and Simulink are quite different. I don't think you can do that because disp() or fprint...

circa 2 mesi fa | 0

Risposto
I can't download Matlab R2022a release or earlier release
I can see many versions on this link. https://www.mathworks.com/downloads/

circa 2 mesi fa | 0

Risposto
How to change const variable during simulink runtime
While the simulation is running, if you double click the Constant block, change its value from one numeric value to another (e.g...

circa 2 mesi fa | 0

Risposto
Initial condition from external source for discrete integration diuring runtime
The value of "mec_init_pos" could be constant or dynamic, but in this case, only its value at the begining of the simulation (e....

circa 2 mesi fa | 1

| accettato

Risposto
Function Call Trigger Problem
This "Outport" block seems to output a function call trigger. The message tells you what type of block can receive this signal. ...

circa 2 mesi fa | 0

Risposto
A few basic Simulink/Simscape questions
run forever (tstop = inf) Yes. Set the simulation stop time to be inf store the trailing 10000 points Yes. Limit the data poi...

circa 2 mesi fa | 0

| accettato

Risposto
How the Delay one step block and stop time ( simulation time) infuence each other on simulink?
If you don't specify the step size or it is auto, the step size is automatically adjusted, influnced by simulation stop time and...

circa 2 mesi fa | 0

Risposto
Simulink model output heavily dependent on relative tolerance
Not typical but is for a stiff system. Choose a stiff solver. https://www.mathworks.com/help/matlab/math/solve-stiff-odes.html

circa 2 mesi fa | 0

Carica altro

Go to top of page