Problem with Simulink Integrator block

4 visualizzazioni (ultimi 30 giorni)
Milo
Milo il 13 Ago 2014
Commentato: Ranjeet il 25 Feb 2024
I'm trying to integrate a data stream that is single precision and keep getting the follow error:
Only 'double' signals are accepted by block type Integrator. The signals at the ports of
'Model/Integrator2' are of data type 'single'.
The data is coming from a simulink "From File" block which is loading a 1x1 single timeseries.
Is there a way to convert the data stream from single to double in Simulink? Or a better way to import this data? It seems that timeseries are always single precision. The timeseries was created from two vectors of equal length. One vector is a series of timesteps, the other a series of data points.

Risposta accettata

A Jenkins
A Jenkins il 13 Ago 2014
Did you try a Data Type Conversion block?

Più risposte (1)

Yu Jiang
Yu Jiang il 13 Ago 2014
Yes, there is a block called Data Type Conversion. See the following for details: http://www.mathworks.com/help/simulink/slref/datatypeconversion.html