Interafacing data converter with fixed point model
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
I have a fixed point model with inputs in the range -0.5 to +0.5 and datatype-fixdt(1,32,31). It simulates well as expected.
Next, I need to interface with simulink data converter block and check the response from this model. I have set the voltage range as -10V to +10V and output data type as int 16. Then I used the convert datatype model to perform the translation of ADC outputs(int16) to fixdt(1,32,31). But I get the outputs from the model as zero. Could anybody guide me in this regard to solve this problem?
0 Commenti
Risposte (1)
Muthukumar Ganesan
il 23 Lug 2022
Hi,
fixdt(1,32,31) can represent the range -1 to +1. Since initially your voltage range is -0.5 to +0.5, you get proper results. In the modified range -10 to +10, this cannot be fully represented in fixdt(1,32,31). You have to increase the word length fixdt(1,36,31) or decrease fraction length fixdt(1,32,27).
Hope this helps.
Thanks
Vedere anche
Categorie
Scopri di più su Sources in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!