Store and re-use data from protected model

1 visualizzazione (ultimi 30 giorni)
I have to share a protected model to a third party.
In the protected model I have some data store memory and signals which can be open to the third party.
I want to store these values at the end of simulation and initialize the simulation from the same values.
Currently logging gets disabled after adding protection.

Risposta accettata

Ayush Singh
Ayush Singh il 16 Feb 2024
Modificato: Ayush Singh il 16 Feb 2024
Hi Shivam
I assume you have some data store memory and signals which you want to store at the end of simulation and use those values for initialization.
Signal logging being disabled for a protected model is expected behaviour.
However, there are three ways to let the end user access internal signals in the Protected Model:
  1. Bring the signal to the top level using an output port on the Model.
  2. Use a "To File" block inside the Model to log the signals
  3. Use a "To Workspace" block inside to log the signals
I hope the above information helps.
  2 Commenti
Shivam garg
Shivam garg il 16 Feb 2024
Hi Ayush,
Yes that is what I am trying to do. Let me try the To Workspace block. will it work even inside protected model?
Ayush Singh
Ayush Singh il 16 Feb 2024
Yes 'To Workspace' will work for protected model

Accedi per commentare.