simulink -sinx integral

Risposte (1)

Paul
Paul il 19 Mag 2024
Modificato: Paul il 20 Mag 2024

2 voti

Hi 승표,
It's not really an offset. The Integrator block parmameter 'Initial Condition' is set to zero, which corresponds to setting the constant of integration C = -1 in the solution for the antiderivative. Double click on the Integrator block and set the Initival Condition parameter to whatever is needed to get the desired result.
Another way to think of it is that the output of the Intregator block is: x0 + int(-sin(tau) dtau, from 0, to x)
(thought it it looks like your actual, input sine wave is at a higher frequency).

Categorie

Scopri di più su Simulink in Centro assistenza e File Exchange

Prodotti

Tag

Richiesto:

il 19 Mag 2024

Modificato:

il 20 Mag 2024

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by