How to model a 50MW battery energy storage in simulink, how should the parameters be set, why I set up a light storage combined system, but the output power is not always up t
19 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
How to model a 50MW battery energy storage in simulink, how should the parameters be set, why I set up a light storage combined system, but the output power is not always up to
I want to make a 50MW battery storage and fan combined, what should I do![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1736836/image.png)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1736836/image.png)
0 Commenti
Risposta accettata
Joel Van Sickel
il 3 Set 2024
knowing that it is 50 mW only tells power. This would likely let you spec out your terminal resistance (which would need to be low). However, you aren't addressing the real issue, which is total eneryg stored. 50 MW for 10 minutes if very different than 50 MW for 10 hours. You will need to calculate your amp hours from that value (power * time / voltage) If you wnat to also add a fan, I recommend swiching to simscape instead of using specialized power systems, as it will make modelling the mechanical domain (and cooling) much easier. Then you can use simscape battery to build up any size battery pack you want based on power and energy levels.
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Sources in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!