Cannot run Referenced model in accelerator mode
22 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I am unable to run a referenced model in accelerator, I have no issue doing so when the model is opened as the top model but once it is included in another model and individually set to accelerator while the rest of the model is set to normal, then it doesnt work.
Invalid run-time parameter registration in S-function 'sfun_spssw_discc' in model 'MyModel'. An S-function can register run-time parameters only if the S-function is being inlined. To be able to reference the model 'MyModel', the S-function 'sfun_spssw_discc' needs to set the option SS_OPTION_USE_TLC_WITH_ACCELERATOR and it needs to have a TLC file.
I am not intentionally using any S - functions so I am a little unsure what to do with this error message
2 Commenti
Gayathri
il 20 Nov 2024
@Jake Gareau, Can you provide the simulink models so that I can take a look to find the issue.
Risposta accettata
Abhas
il 3 Dic 2024
To address this issue, try using "powergui". Navigate to "preferences" and enable the option called "Use TLC file when in Accelerator Simulation Mode and for code generation".
You can refer the below MathWorks documentation links to have a better understanding:
- https://www.mathworks.com/help/sps/powersys/ref/powergui.html#mw_081370b9-45b5-4a1f-9710-94f3835bf2cc
- https://www.mathworks.com/help/simulink/sfg/ss_option_use_tlc_with_accelerator.html
I hope this helps!
0 Commenti