Battery Aging model rainflow counting
    17 visualizzazioni (ultimi 30 giorni)
  
       Mostra commenti meno recenti
    
I have a SOC(t) profile for a Li ion battery in an electric truck. My model considers average SOC and depth of discharge (DOD) as cycling aging factors. I need to count the number of cycles in the SOC profile to obtain average SOC and DOD for each cycle. I'm going to use rainflow counting.
Before the actual counting, I'm going to do hysteresis (and peak-valley) filtering. Here is the SOC(t) profile before any processing.
How wide should the hysteresis gate be?

0 Commenti
Risposte (1)
  Ameen Bassam
 il 12 Apr 2025
        The amount of cycling is commonly stated in full equivalent cycles (FECs), by scaling the total charge throughput Q with the battery capacity C_batt in Ah:
Q = integration of current with time
FEC = Q/(2*C_batt)
0 Commenti
Vedere anche
Categorie
				Scopri di più su Energy Production in Help Center e File Exchange
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!