Here is the model
Spectrum block shows incorrect dbm value
5 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Dear all,
In the attached model NCO generates a sine wave of 32MHz and spectrum is set to RBW of 1MHz, 50Ohm resistance. We can see in the Spectrum, that the peak value in dbm is 6.9823, which corresponds to a peak-to-peak voltage of 1.413V. However, in the scope block we can see, that the signal amplitude is 2V peak-to-peak, which corresponds to 10dbm (dbm = 10*log10(1000*Vrms^2/R)). Why so?
The model is attached.


Thank you!
4 Commenti
Mathieu NOE
il 1 Lug 2025
hello
"funny" was maybe not the most appropriate word, I was just suggesting that there is somewhere a mistake as somewhere we use Vrms instead of Vpeak and that's why we see a 3 dB difference
but as I can't open your slx file (because I run R2020a release) I can't say for sure where the confusion may come from
Risposta accettata
David Goodmanson
il 18 Lug 2025
Modificato: David Goodmanson
il 18 Lug 2025
Hi Sergei,
The plot shows peaks at both positive and negative frequencies. Each of those equal size peaks contains half of the power, so each peak will be down by a factor of 2, and
10dBm - 10*log10(2) = 6.9897dBm
Più risposte (0)
Vedere anche
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!