I have boost converter with PID controller. I need to linearization to plot bode diagram without transfer function. But everytime I try I cant determine diagram unless put an output mesasurement to output of PID. There was no data when I want to measure data from plant output.
The diagram I have attached belong to PID output not converter.
Risposte (2)
Andrew Ouellette
35 minuti fa
0 voti
What happens when you try to linearize your boost converter? Do you receive an error? Do you receive a linearization D=0?
Can you succcessfully linearize other models? Have you tried using the linearization advisor to find problematic blocks?
Have you tried frequency response estimation?
mehmed celebi
circa 13 ore fa
0 voti
2 Commenti
Andrew Ouellette
circa 12 ore fa
Okay, so it sounds like you are trying to do frequency response estimation rather than linearization. The error message is pointing to a mismatch between the perturbation signal you have defined and (at least one) location where you are trying to inject the signal. The sinestream perturbation signal can have a variable number of sample times. When you define such a sinestream, you need to inject the perturbation on continuous time [0 0] or fixed in minor time step [0 1] signals. Most likely, you are trying to inject the perturbation on a discrete time signal. Try creating a fixed sample time sinestream instead as the error message suggests.
mehmed celebi
circa 11 ore fa