Control algorithm stops working after 5 min 30 sec on F28335.
2 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I want to generate A sin(Wt) with A and W as external signals. As shown in figure i have done that. Sample time for blocks is 50e-6. I am using this block in inverter control algorithm. After downloading code on F28335 controller, it stops controlling after 5 min 30 sec. p.s. if i use inbuilt sine source block, it works fine. But, i want A and W configurable from external signals.
0 Commenti
Risposte (1)
Jeevan Thomas
il 11 Set 2015
Spostato: Sabin
il 20 Dic 2022
Did you make sure that you gave the same "50e-6" as sample time for all the blocks including "Digital Clock" block? "Digital Clock" has a default sample time of 1 sec. If it is not set to the base sample time, your application might terminate prematurely based on the end time of Simulation set in model.