Simulink: Scope time scale

I am simulating the model for 2 seconds, but the scope shows a time history of 0.8 to 2 seconds only, even if i use the autoscale. if i simulate for 1 sec some times shows upto 0.9 to 1 seconds.
please help....thanks in advance

 Risposta accettata

Andreas Goser
Andreas Goser il 10 Feb 2012

0 voti

Funny - just yesterday, I answered such a thing here.
It is about the " Limit Data Point to last" setting.

5 Commenti

Kiran Sagar
Kiran Sagar il 10 Feb 2012
I already unchecked it....still doesn't work
Andreas Goser
Andreas Goser il 10 Feb 2012
OK, so one step back then. We need to see whether it is a display thing only, or a calculation issue. Can you add a "to workspace block" at the end of the same signal the scope is and then see if the saved data is according your expectations?
Kiran Sagar
Kiran Sagar il 10 Feb 2012
yes, u r right...to workspace works, i am getting the whole data
Kiran Sagar
Kiran Sagar il 10 Feb 2012
i guess its a display issue...
Andreas Goser
Andreas Goser il 10 Feb 2012
I received your model. I can't run it as of the missing data, but all scopes have the " Limit Data Point to last" setting checked.

Accedi per commentare.