Simulink showing error. kinematic constraints cannot be maintained. Check solver type and consistency tolerance in the Simscape Solver Configuration block.

136 visualizzazioni (ultimi 30 giorni)
Hello,
I'm using simulink to get joints torque by giving motion input. I create very simple CAD model in solidworks to learn simulink. Simulink model is showing in below figure.
During update it shows no error but when I Run it shows error as
3D-CAD model is shown below figure.
Can anybody help me to solve this problem.
Thanks.

Risposte (1)

jack javons
jack javons il 6 Gen 2020
Modificato: jack javons il 6 Gen 2020
maybe you can change the parameters about Consistency tolerance of solver configuration,such as change the 1e-09 to 1e-06 or a larger number, also you maybe need to change the solver selection ,by did so ,I have Solve the problem.

Categorie

Scopri di più su General Applications in Help Center e File Exchange

Prodotti

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!