Equilibrium point simpower system multimachine model.
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
If I run a load flow, I suppose that the states relates to a simplified synchronous machine remain constant until a disturb occur, but when I run a Phasor simulation, the Rotor angle and the Rotor speed present a little variation. So, Can this little variation be given by the solution calculated for the numeric method?
0 Commenti
Risposte (1)
Joel Van Sickel
il 17 Set 2020
Hello Luis,
in phasor simulation, everything is held to a fixed frequency. If you want to explore the dynamics of rotor speed changing, I would recommend using a continuous simulaiton instead. This still works with initializaiton through load flow. However, the fact that rotor angle isn't changing is problematic unless your rotor speed is zero. I wonder if something else is wrong.
Regards,
Joel
0 Commenti
Vedere anche
Categorie
Scopri di più su Simscape Electrical in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!