AnalysisPoint fails when using multiple connect commands
Mostra commenti meno recenti
I am attempting to connect multiple control subsystems (G1, G2) using the connect command. Each subsystem has analysis points connected to internal signals. I get an error when I connect the subsystems and attempt to keep the analysis points. The issue seems to be related to using multiple instances of the connect command. My current workaround is to use the connect command once. However, for building up large systems with multiple transfer functions this seems unwieldy.
Example code showing the problem is given below. I want to have access to analysis points "InnerError" and "OuterError" in the full model.
G1 = tf([1],[1 0]);
G1.u = 'OuterError';
G1.y = 'InnerCmd';
G2 = tf([1], [1 1]);
G2.u = 'InnerError';
G2.y = 'ActuatorCmd';
SumOuter = sumblk('OuterError = OuterCmd - Outer');
SumInner = sumblk('InnerError = InnerCmd - Inner');
disp('Connect everything at once. This works.')
Sys1 = connect(G1,G2,SumOuter,SumInner,{'OuterCmd','Outer','Inner'},'ActuatorCmd', {'InnerError','OuterError'})
disp('Connect things in series. This does not work with AnalysisPoints.')
P1 = connect(G1,SumOuter,{'OuterCmd','Outer'},'InnerCmd','OuterError');
P2 = connect(G2,SumInner,{'InnerCmd','Inner'},'ActuatorCmd','InnerError');
Sys2 = connect(P1,P2,{'OuterCmd','Outer','Inner'},'ActuatorCmd', {'InnerError','OuterError'});
Risposta accettata
Più risposte (0)
Categorie
Scopri di più su Setup for Tuning MATLAB Models in Centro assistenza e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!