Hello every one. can some one help me with this?
    1 visualizzazione (ultimi 30 giorni)
  
       Mostra commenti meno recenti
    
    Luana Aragao
 il 25 Giu 2018
  
    
    
    
    
    Commentato: Walter Roberson
      
      
 il 25 Giu 2018
            Hello every one, I'm an electrical engineering student, and I'm trying to modelling and simulating a hydroeletric power plant.l I'm new at matlab and simulink, so i'm having lot of doubts about that.
I projected a station just like that bellow:


After that, when i try to compilate the project, i got this error:

I really have no idea about how to fix it. Can some one please help me with this? Thank you all :)
0 Commenti
Risposta accettata
  Walter Roberson
      
      
 il 25 Giu 2018
        You need to resolve the link into the bottom of the Local Load block, in order to provide a value for the VRated input.
You need to open the Machine Mechanical Power (SI) block and look at the parameter fElectrical0 which you will find that you have defined in terms of FRated, but you have not defined FRated
You need to open the Reactive Compensation block and look at the parameter C which you will find that you have defined in terms of reactiveCompensationCapacitance, but you have no defined reactiveCompensationCapacitance
See https://www.mathworks.com/help/simulink/ug/parameter-values-and-specification-methods.html for ways you can define those parameters.
2 Commenti
  Walter Roberson
      
      
 il 25 Giu 2018
				You can try either of those recommended actions.
However, probably you will need to remove the algebraic loop. See https://blogs.mathworks.com/simulink/2015/07/18/why-you-should-never-break-an-algebraic-loop-with-with-a-memory-block/
Più risposte (0)
Vedere anche
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!

