How to set initial condition y(1)=1 in solving ODE using Simulink?

10 visualizzazioni (ultimi 30 giorni)
Can anyone guide me how can I set initial conditions for ODE in Simulink. It is easy to set Y(0)=0 or 1 in integerator. How to set Y(1)=1 in integrator.
I wanna solve dy/dt= (2/t) y , where y(1)=1 as initial condtions in Simulink.
  2 Commenti
Aquatris
Aquatris il 26 Dic 2018
If y(1) = 1 is your initial condition, it means your starting "time" is 1. Why not just set the integrator initial to 1 and offsett the time value whereever it appears in your equations?

Accedi per commentare.

Risposte (1)

Akshay Khadse
Akshay Khadse il 28 Dic 2018
As Aquatris mentioned, the Start Time for simulation should be specified as 1 from the Configuration Parameters.
Then, you can specify the initial condition using any of the following methods:
1) Specify the Initial condition in the Integrator block parameters as 1. OR
2) Use Simulink.BlockDiagram.getInitialState as follows
x0 = Simulink.BlockDiagram.getInitialState(gcs);
x0{1}.Values.Data = 1;
Please refer the following documentation page to know more about the Simulink.BlockDiagram.getInitialState