GUI in MATLAB/SIMULINK-ActiveX error
2 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I was using a GUI in a simulink model. The code for the gui was written in MATLAB 2012, but the simulink model is created in 2017. When I try to integrate the gui and simulink model together and run, it gives the following error:
Input PROGID does not represent an ActiveX control. If this PROGID used to work before, please check vendor's documentation for equivalent activex control progid.
How to solve thsi issue?
0 Commenti
Risposte (1)
Agnish Dutta
il 5 Feb 2020
Modificato: Agnish Dutta
il 5 Feb 2020
One possible source of this error is when you try to run 32-bit ActiveX controls with 64-bit MATLAB. This isn't supported at the moment and is a limitation of the 64-bit Windows operating system. ActiveX controls are "in-process" COM objects which can not be used by 64-bit applications.
The workaround is to install a 32-bit version of MATLAB on the 64-bit machine.
Please let us know if the above is indeed the root of the issue and feel free to revert to this thread for any further queries.
0 Commenti
Vedere anche
Categorie
Scopri di più su ActiveX in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!