Why does LinearFMWaveform require integer Sampling Rate / PRF ratios?
Mostra commenti meno recenti
Does anybody know why the LinearFMWaveform demands that this condition be met:
The quantity (SampleRate ./ PRF) is a scalar or vector that must contain only integers.
I am modeling a radar with a fixed sampling rate and a discrete set of PRFs. But I cannot make side-by-side comparisons when I have to change the sampling rate for each waveform. Does anybody know a way around this behavior?
Risposte (1)
Honglei Chen
il 5 Ott 2012
0 voti
Hi Michael,
The pulse supposed to repeat itself at the PRF. If the ratio is not an integer, then the waveform cannot be started from the beginning. As a consequence, the LinearFMWaveform also cannot really output one pulse a time because a pulse is not represented by the integer number of points.
This being said, I am very curious about your case here. Would you mind sharing that in such a situation, how you would like the waveform to behave?
Thanks.
1 Commento
Michael Matuson
il 8 Ott 2012
Categorie
Scopri di più su Pulsed Waveforms in Centro assistenza e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!