Azzera filtri
Azzera filtri

Standalone PV array producing negative voltage.

10 visualizzazioni (ultimi 30 giorni)
EngTat Chung
EngTat Chung il 11 Mar 2020
Spostato: Sabin il 4 Gen 2023
I am trying to compare the power from my pv array and my battery to the load. I noticed my PV array power is negative and I am not sure why. The output power is also very low compared to my input from PV array and Battery. Please refer to the attached PDF file for the images.
Please I would like to seek assistance on this issue.

Risposte (1)

Jonathan LeSage
Jonathan LeSage il 13 Mar 2020
Spostato: Sabin il 4 Gen 2023
I took a look at the schematic and I don't see anything immediately wrong. I would recommend commenting out the battery model to start and have the model run with only the PV array as the source. Once you confirm that this can provide the correct power load to the motor, work on adding back the battery.
The other thing that comes to mind is that the MPPT algorithm for solar might affect the DC bus voltage, which effects the converter for the battery system. You could change the solar inverter controller to hold a steady DC bus and then use the battery to charge/discharge. You could use something similar to the following example:
>> parallel_battery_SC_boost_converter