Azzera filtri
Azzera filtri

Simulink Variant, missing "Override Using" context menu

3 visualizzazioni (ultimi 30 giorni)
I have .slx models provided to me by software writers. These models use Variants. In 2016b there is a context menu "Override Using" that is not present in 2019a. How do I replicate this action with 2019a?
Below is 2019a
Below is 2016b

Risposta accettata

Sai Sri Pathuri
Sai Sri Pathuri il 5 Mag 2020
From R2019a, the Override variant conditions and use the following variant option no longer exists. To get the same functionality, use the Label option in Variant control mode instead.
The label mode allows you to specify the name-based variant controls (Label mode active choice). In label mode, the variant control is not evaluated and the choice used in simulation is determined by the Label mode active choice parameter.
Additionally, to choose the active variant based on the evaluation of variant conditions, select Expression as the variant control mode. In expression mode, the variant control can be a Boolean expression, a Simulink.Variant object containing a Boolean expression, or ‘(default)’.
However, Simulink models that were created prior to R2019a with Override variant conditions and use following variant option will continue to work when you update the model to a newer version.
  1 Commento
Smattering_Applause
Smattering_Applause il 8 Mag 2020
To help people parse the instructions down, here's some snippets of what to do.
  1. Right click on the model you would have used "Override Using" on. Select "Block Parameters (Subsystem"
2. Change the Variant Control Mode to "Label"
3. Change the "Label mode active choice" to the Variant Label you want to have active. Then hit "OK" or "Apply" to have them take effect