Cannot select signal when using Powergui FFT Analysis Tool -Empty-

29 visualizzazioni (ultimi 30 giorni)
I am trying to use the FFT Analysis tool on the "powergui" block but I am not able to select the signal that I want to analyze on the drop-down menu. The name and input field only display "-Empty-".
Am I missing some steps?

Risposta accettata

MathWorks Support Team
MathWorks Support Team il 12 Mar 2021
Below are some steps you would need to do:
  1. Go to model Configuration Parameter and select Data Import/Export pane on the left
  2. Untick the Single simulation output and click on Apply
  3. Double click the "Scope" block at which the signals are connected, right click and select Configuration Properties, go to Logging and select Log data to the workspace and select Structure with Time and click on Apply
  4. Run the simulation
  5. Double click "powergui" block and select FFT Analysis from the Tools tab
  6. Now you should be able to select the signals from the list

Più risposte (0)

Categorie

Scopri di più su Data Logging in Help Center e File Exchange

Tag

Non è stata ancora inserito alcun tag.

Prodotti


Release

R2020a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!