Solver for common mode noise

hi
i have a three phase inverter simulation based on SPICE models.I am trying to obtain the common-mode noise level of this inverter using Spectrum Analyzer in simulation.I want to know your suggestions about choosing the right solver (Also state the reason for your suggest).

 Risposta accettata

Rick Hyde
Rick Hyde il 4 Gen 2021

0 voti

For Simscape models, you should in general choose an implicit solver e.g. ode23t, ode15s or daessc. However, results should be comparable for all solvers provided that you pick abstol and reltol values that reflect the accuracy you need. It is best practice not to use the "auto" abstol option; better to take control and set the value that you need. Ensuring the max step size is not too large can also help simulation speed by reducing the number of solver resets.
Please see this example which may help with setting up your model:
Regards
Rick Hyde

Più risposte (0)

Community

Più risposte nel  Power Electronics Control

Categorie

Richiesto:

il 26 Dic 2020

Risposto:

il 4 Gen 2021

Community Treasure Hunt