Error in Simulink

what kind of error is this?
"Simscape components in Celula are not connected to a Solver Block." Celula is the name of the program...

1 Commento

Arnaud Miege
Arnaud Miege il 9 Mag 2011
Please don't email me directly. As Rob pointed, and as the error message suggests, you need to connect your Simscape network to a Solver Block. I would suggest your read the documentation, in particular the section entitled "Modeling Physical Systems":
http://www.mathworks.com/help/releases/R2011a/toolbox/physmod/simscape/ug/bp5oili.html
Arnaud

Accedi per commentare.

Risposte (1)

Rob Graessle
Rob Graessle il 9 Mag 2011

3 voti

When your block diagram contains Simscape components, the physical network circuit must be connected to at least one Solver Configuration block. This block specifies parameters for the simulation of the physical model.

1 Commento

Arnaud Miege
Arnaud Miege il 9 Mag 2011
Actually, it's *exactly* one Solver Configuration per Simscape network.

Accedi per commentare.

Richiesto:

il 9 Mag 2011

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!