Fmincon requires SQP algorithm

10 visualizzazioni (ultimi 30 giorni)
SEEmULATER
SEEmULATER il 23 Giu 2021
Commentato: SEEmULATER il 30 Giu 2021
When I run fmincon with SQP algorithm, I get no problems. However, when I switch to 'active-set' or 'interior-point', I get the error:
OPTIMOPTIONS property 'Algorithm' must be one of the following values for fmincon:
'sqp', 'sqp-legacy'
I'm trying to use a different algorithm because the documentation says that interior-point can run faster for sparse problems, so I want to test that.
  4 Commenti
Swatantra Mahato
Swatantra Mahato il 29 Giu 2021
Hi
Looking at the error message, I am assuming that you are using the funciton 'fmincon' with code generation, in which case 'sqp' and 'sqp-legacy' are indeed the only algorithms fmincon supports. This is mentioned in the documentation
If this is not the case, can you let me know the version of MATLAB and Operating system you are using, and if possible, share the code you are getting the error with so I can replicate the issue on my end?
Thanks
SEEmULATER
SEEmULATER il 29 Giu 2021
Hi
I am not using code generation. I am using MATLAB 2020b on Ubuntu 20.04. Thank you for looking at this! The files are attached. Run the Sim_Working.m script.

Accedi per commentare.

Risposta accettata

Swatantra Mahato
Swatantra Mahato il 30 Giu 2021
Hi,
It looks like the error shows up in the MATLAB Funciton Block. Kindly refer the following documentation link on how MATLAB Function Blocks work
In particular, note that "C/C++ code generation limitations for MATLAB Coder also apply to MATLAB Function blocks.". To use a different algorithm for your simulation you can use "coder.extrinsic" and refactor your code as mentioned in the below link
Hope this helps

Più risposte (0)

Categorie

Scopri di più su Get Started with Optimization Toolbox in Help Center e File Exchange

Prodotti


Release

R2020b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by