Chen correlation wall temperature calculation

Calculation of pipe wall temperature using the 1963 Chen correlation for subcooled boiling flow
656 download
Aggiornato 21 ott 2013

Visualizza la licenza

This function uses the 1963 Chen correlation for subcooled boiling flow to calculate the wall temperature of a pipe, based on inlet pressure, an initial guess of the pressure at the pipe wall, and three constants: A, B, C
A = h_pb*S, h_pb is the pool boiling coefficient, and S is the Chen suppression factor
B = h_c, h_c is the forced convection coefficient
C = h_c*(Tsat - Tbulk) - q'', Tsat is the saturation temperature of the water in the pipe at the inlet pressure, Tbulk is the temperature of the bulk fluid, q'' is the heat flux of the pipe to the fluid.
This function makes use of the Steam Tables uploaded by Magnus Holsten.

Cita come

Danyal Mohaddes Khorassani (2024). Chen correlation wall temperature calculation (https://www.mathworks.com/matlabcentral/fileexchange/44014-chen-correlation-wall-temperature-calculation), MATLAB Central File Exchange. Recuperato .

Compatibilità della release di MATLAB
Creato con R2012b
Compatibile con qualsiasi release
Compatibilità della piattaforma
Windows macOS Linux

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!
Versione Pubblicato Note della release
1.0.0.0